<?xml version="1.0" standalone="yes" ?>
<!DOCTYPE ProcessorListMSP430 
[	<!ELEMENT ProcessorListMSP430 (Processor+)>
	<!ELEMENT Processor (DeviceType+,Configure+)>
	<!ATTLIST Processor 
		Name CDATA #REQUIRED
		bHasLOCKA CDATA #REQUIRED
		bIsMSP430X CDATA #REQUIRED
		nEMEX CDATA #REQUIRED
		DeviceType CDATA #REQUIRED
		InfoStart CDATA #REQUIRED
		InfoSize CDATA #REQUIRED
		InfoSeg CDATA #REQUIRED
		MainStart CDATA #REQUIRED
		MainSize CDATA #REQUIRED
		MainSeg CDATA #REQUIRED
		>
	<!ELEMENT DeviceType EMPTY>
	<!ATTLIST DeviceType 
		Name CDATA #REQUIRED
		>
	<!ELEMENT Configure EMPTY>
	<!ATTLIST Configure 
		nMode CDATA #REQUIRED
		nValue CDATA #REQUIRED
		>
]>
<ProcessorListMSP430>
	<Processor 	
		Name = "MSP430F1101"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_NONE"
		InfoStart = "0x00001080"
		InfoSize =  "0x00000080"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000FC00"
		MainSize =  "0x00000400"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F11x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1111"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_NONE"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F11x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1121"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_NONE"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000F000"
		MainSize =  "0x00001000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F11x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1101A"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001080"
		InfoSize =  "0x00000080"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000FC00"
		MainSize =  "0x00000400"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F11x1A" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1111A"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F11x1A" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1121A"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000F000"
		MainSize =  "0x00001000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F11x1A" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1122"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000F000"
		MainSize =  "0x00001000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F11x2" />
		<DeviceType Name = "MSP430F12x2/F11x2" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1132"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F11x2" />
		<DeviceType Name = "MSP430F12x2/F11x2" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F122"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000F000"
		MainSize =  "0x00001000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F12x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1222"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000F000"
		MainSize =  "0x00001000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F12x2/F11x2" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F123"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F12x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1232"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F12x2/F11x2" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F133"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F133" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1331"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F133" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F135"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F135" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1351"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F135" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F147"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F147" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1471"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F147" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F148"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F148" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1481"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F148" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F149"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00001100"
		MainSize =  "0x0000EF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F149" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1491"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00001100"
		MainSize =  "0x0000EF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F149" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F155"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F155" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F156"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000A000"
		MainSize =  "0x00006000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F156" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F157"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F157" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1610"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F1610" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1611"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F1611" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F1612"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00002500"
		MainSize =  "0x0000DB00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F1612" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F167"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F167" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F168"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F168" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F169"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00001100"
		MainSize =  "0x0000EF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F169" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2001 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000FC00"
		MainSize =  "0x00000400"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2001 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000FC00"
		MainSize =  "0x00000400"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2002 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000FC00"
		MainSize =  "0x00000400"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x2" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2002 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000FC00"
		MainSize =  "0x00000400"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x2" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2003 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000FC00"
		MainSize =  "0x00000400"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x3" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2003 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000FC00"
		MainSize =  "0x00000400"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x3" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2011 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2011 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2012 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x2" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2012 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x2" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2013 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x3" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2013 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F20x3" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2101"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000FC00"
		MainSize =  "0x00000400"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F21x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2111"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F21x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2112 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2112" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2112 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F800"
		MainSize =  "0x00000800"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2112" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2121"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F000"
		MainSize =  "0x00001000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F21x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2122 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F000"
		MainSize =  "0x00001000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2122" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2122 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000F000"
		MainSize =  "0x00001000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2122" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2131"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F21x1" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2132 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2132" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2132 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2132" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2232 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2232" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2232 (SBW)"
		bIsMSP430X = "FALSE"
		bHasLOCKA = "TRUE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2232" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2234 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2234" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2234 (SBW)"
		bIsMSP430X = "FALSE"
		bHasLOCKA = "TRUE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2234" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2252 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2252" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2252 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2252" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2254 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2254" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2254 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2254" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2272 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2272" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor
		Name = "MSP430F2272 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2272" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F2274 (4-wire)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2274" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIREJTAG_IF" />
	</Processor>
	<Processor
		Name = "MSP430F2274 (SBW)"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2274" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
		<Configure nMode = "INTERFACE_MODE" nValue = "SPYBIWIRE_IF" />
	</Processor>
	<Processor 	
		Name = "MSP430F233"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F233" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2330"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2330" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F235"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F235" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2350"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2350" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2370"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2370" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2410"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00002100"
		MainSize =  "0x0000DF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2410" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2416"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00002100"
		MainSize =  "0x00016F00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2419" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2417"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00003100"
		MainSize =  "0x00016F00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2418" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2418"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00003100"
		MainSize =  "0x0001CF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2418" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2419"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00002100"
		MainSize =  "0x0001DF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2419" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F247"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F247" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2471"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2471" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F248"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F248" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2481"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2481" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F249"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00001100"
		MainSize =  "0x0000EF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F249" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2491"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_MEDIUM"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00001100"
		MainSize =  "0x0000EF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2491" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2616"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00002100"
		MainSize =  "0x00016F00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2619" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2617"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00003100"
		MainSize =  "0x00016F00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2618" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2618"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00003100"
		MainSize =  "0x0001CF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2618" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F2619"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00002100"
		MainSize =  "0x0001DF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F2619" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F412"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000F000"
		MainSize =  "0x00001000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F41x" />
		<DeviceType Name = "MSP430FW42x/F41x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F413"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F41x" />
		<DeviceType Name = "MSP430FW42x/F41x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F415"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F41x" />
		<DeviceType Name = "MSP430FW42x/F41x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F417"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F41x" />
		<DeviceType Name = "MSP430FW42x/F41x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F423"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F423" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F423A"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F423A" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F425"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F425" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F425A"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F425A" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F427"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F427" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F427A"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F427A" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F4230"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F4230" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F4250"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F4250" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F4270"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F42x0" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F435"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F43x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F436"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000A000"
		MainSize =  "0x00006000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F43x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F437"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F43x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F447"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F44x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F448"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F44x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F449"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00001100"
		MainSize =  "0x0000EF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F44x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F4783"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F4783" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F4784"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F4784" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F4793"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00001100"
		MainSize =  "0x0000EF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F4793" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430F4794"
		bHasLOCKA = "TRUE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000040"
		MainStart = "0x00001100"
		MainSize =  "0x0000EF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430F4794" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FE423"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FE423" />
		<DeviceType Name = "MSP430FE423_P" />
		<DeviceType Name = "MSP430FE423_N" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FE423A"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FE423A" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FE425"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FE425" />
		<DeviceType Name = "MSP430FE425_P" />
		<DeviceType Name = "MSP430FE425_N" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FE425A"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FE425A" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FE427"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FE427" />
		<DeviceType Name = "MSP430FE427_P" />
		<DeviceType Name = "MSP430FE427_N" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FE427A"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FE427A" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FG437"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FG43x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FG438"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00004000"
		MainSize =  "0x0000C000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FG43x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FG439"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00001100"
		MainSize =  "0x0000EF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FG43x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FG4616"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00002100"
		MainSize =  "0x00016F00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FG461x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FG4617"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00003100"
		MainSize =  "0x00016F00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FG461x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FG4618"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00003100"
		MainSize =  "0x0001CF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FG4618" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FG4619"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "TRUE"
		nEMEX = "EMEX_HIGH"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00002100"
		MainSize =  "0x0001DF00"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FG4619" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FW423"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000E000"
		MainSize =  "0x00002000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FW42x/F41x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FW425"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x0000C000"
		MainSize =  "0x00004000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FW42x/F41x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
	<Processor 	
		Name = "MSP430FW427"
		bHasLOCKA = "FALSE"
		bIsMSP430X = "FALSE"
		nEMEX = "EMEX_LOW"
		InfoStart = "0x00001000"
		InfoSize =  "0x00000100"
		InfoSeg =   "0x00000080"
		MainStart = "0x00008000"
		MainSize =  "0x00008000"
		MainSeg =   "0x00000200" >
		<DeviceType Name = "MSP430FW42x/F41x" />
		<Configure nMode = "VERIFICATION_MODE" nValue = "TRUE" />
	</Processor>
</ProcessorListMSP430>